Warning: A non-numeric value encountered in /storage/content/01/2000401/glahi.se/public_html/wp-content/themes/Avada/includes/dynamic_css.php on line 6515 Warning: A non-numeric value encountered in /storage/content/01/2000401/glahi.se/public_html/wp-content/themes/Avada/includes/dynamic_css.php on line 6526 Warning: A non-numeric value encountered in /storage/content/01/2000401/glahi.se/public_html/wp-content/themes/Avada/includes/dynamic_css.php on line 6529

Adapters

­
    Warning: sizeof(): Parameter must be an array or an object that implements Countable in /storage/content/01/2000401/glahi.se/public_html/wp-content/plugins/woocommerce/includes/wc-conditional-functions.php on line 239
  • All connectors have an overall length of approximately 50 mm. Measures: GL Thread


  • Used in fabrication of various types of apparatus. Measures: GL Thread, Approx. overall length (mm)


  • All connectors have an overall length of approximately 80 mm. Measures: Glass Stopcock bore size (mm), GL Thread


  • Connecting, offset

    236.50 kr

    For use with multiple entry NS flasks or reaction vessels. Measures: NS Joints, Approx. overall height (mm), Offset (mm)


  • For connecting dissimilar NS joints. Outer joint is at the top, inner at the bottom. Measures: NS K joints, NS H joints


  • Expands length of apparatus and is also useful as an air condenser. Measures: NS Joints, Overall Length (mm), Length between NS joints (mm)


  • Direct drip

    251.00 kr

    NS Joints with curved drip tube. Measures: NS Joints, Approx Overall height (mm)


  • Used to transfer fluids between two flasks or as a one-piece distillation unit. A variety of flasks or adapters may be connected to this unit to use at reduced pressure or under an inert atmosphere. Measures: NS Joint, Approx. Overall height x width (mm)


  • With a NS outer joint at top. Tapered drip tube extends into open receivers. Measures: NS Joint, Approx. overall height x width (mm)


  • With NS inner joints at each end. Measures: NS Joints, Approx. overall height x width (mm)


  • For entries into a variety of flasks. Measures: NS Joint bottom, NS Joint top (small), NS Joint top (big), Approx. overall height x width (mm), Pkg. Qty


  • For use as a component in atmospheric or vacuum distillations. Measures: NS Joints (lower), NS Joint (top), Approx overall height x width (mm)


  • Distilling

    299.20 kr

    Useful in the sub-boiling separation of mixtures having volatile components. Joints are parallel. Measures: NS Joints, Distance between NS Joints (mm)


  • Distilling trap

    353.10 kr

    Placed above a boiling flask to prevent foaming-type reactions from entering either the distilling column or the condenser. Particularly useful with rotary evaporators. Measures: Top outer NS Joint, Bottom Inner NS Joint, Bulb diameter (mm), Approx. Overall height (mm)


  • With two threaded openings, offset and angled approximately 10 degrees for use with multi-neck flasks. Measures: NS Joint, GL Thread


  • Filtration

    268.40 kr

    For reduced pressure distillation using a suitable glass vessel with an NS joint. Measures: NS Joint, Hose Conn. (mm), Fits Funnel sizes (ml)


  • Inlet, flow control

    510.40 kr

    For regulating the input of gases or liquids into reaction systems. Measures: NS Joint, Hose conn. (mm), Stopcock bore size (mm), Approx. overall height (mm)


  • Inlet, gas

    291.50 kr

    Hose connection provides a gas inlet for reactions. Allows access to the bottom of flasks/tubes. User may shorten the lower tube to fit the flask or apparatus. Measures: NS Joints, Hose conn. (mm), Tube length (mm), Approx. overall height (mm)


  • Inlet, gas/liquid

    116.60 kr

    For the introduction of gases or liquids during reactions. Measures: Approx. body O.D. (mm), Tip I.D. (mm), Hose conn. (mm), Approx. Overall height x width (mm)


  • For the introduction of gases or liquids under reactions. Capillary bleed-type. Measures: NS Joint, O.D. (mm) upper tube, Tip I.D. (mm), Approx length below joint (mm)


  • Inlet, GL

    168.30 kr

    For use with plain thermometers, pipets, syringes or other small items. Measures: NS Joint, GL Thread, Hose Conn. (mm)


  • Inlet, hose

    123.00 kr

    Ideal for use as a vent or for the introduction of pressure/vacuum. Measures: NS Joints, Hose conn. (mm), Approx. overall height (mm)


  • Inlet, hose to ball

    258.00 kr

    Socket joint hose connector. Standard FS sizes fit existing apparatus using spherical joints and permit attachment of flexible hose without costly modification of the apparatus. Measures: FS, Hose connection (mm)


  • Socket joint hose connector. FS sizes fit existing apparatus using spherical joints and permit attachment of flexible hose without costly modification of the apparatus. Measures: FS, Hose conn. (mm)


  • Ideal for use as a vent or for the introduction of pressure/vacuum. Measures: NS Joint, Hose conn. (mm), Approx. overall height (mm)


  • Ideal for use as a vent or for the introduction of pressure/vacuum. Measures: NS Joint, Hose conn. (mm), Approx. overall height (mm)


  • Liquids or gases may be directed into organic reactions. Measures: Approx. O.D. (mm), Tip I.D. (mm), Approx Overall length (mm)


  • Inlet, reactants

    173.00 kr

    Used to introduce reactants below the interior surface. Measures: NS Joint, Hose conn. (mm), Approx. bottom tube length (mm), Approx. overall height (mm)


  • Hose connection on the side Measures: NS Joints bottom, NS Joints top, Hose conn. (mm), Approx. overall height (mm)


  • Inlet, thermometer

    342.00 kr

    Compact adapter with a NS 10/19 upper joint. Side hose connection for gas/vacuum introduction and venting. Measures: NS Joint, Hose conn. (mm), Approx. overall height (mm)


  • Thermometer adapter with a NS 24/29 inner joint at bottom and a NS 10/19 outer joint at the top, offset and inclined from vertical. Measures: NS Joint, Thermometer NS Joint, Approx. overall height (mm)


  • Thermometer adapter with a NS 24/29 inner joint at the bottom and a NS 10/19 outer joint at top, offset and inclined from vertical. Measures: NS Joint, Thermometer NS Joint, Hose conn. (mm), Approx. overall height (mm)


  • Joint at top for a NS ground joint thermometer and a hose connection at side as an additional inlet. Measures: NS Joint, Thermometer NS Joint, Hose conn. (mm), Approx. overall height (mm)


  • Straight type, with NS inner joint at bottom, hose connector at side and tubulature at top. Measures: NS Joint, Hose conn. (mm), Approx. overall height (mm)


  • Vertical adapter with vacuum take-off and drip tip. Measures: NS Joints, Hose conn. (mm), Approx. overall height (mm)


  • With a hose connection for vacuum or the introduction of gases. For use with plain thermometers, pipets, syringes and other small items. Measures: NS Joint, GL Thread, Hose conn. (mm)


  • With two side hose connection for venting or introducing gas/vacuum into a system. Measures: NS Joint, Hose conn. (mm), Approx. Tube length (mm), Approx. overall height (mm)


  • A unique glass adapter, offset and angeled approximately 10 degrees for use with multi-neck flasks. Measures: NS Joint, GL Thread


  • Pour/transfer

    162.00 kr

    Used for more precise pouring of liquids from reactors and NS joint flasks and also to eliminate droplet run-back. Particularly suitable for dry box and remote applications. Measures: NS Joint, Approx. Overall height x width (mm)


  • Syringe needle

    150.00 kr

    When used in conjunction with standard syringes, liquid samples may be added or withdrawn from multiple neck flasks. A syringe needle can also be used as a capillary bleed tube or bubbler. Measures: NS Joint