Warning: A non-numeric value encountered in /storage/content/01/2000401/glahi.se/public_html/wp-content/themes/Avada/includes/dynamic_css.php on line 6515 Warning: A non-numeric value encountered in /storage/content/01/2000401/glahi.se/public_html/wp-content/themes/Avada/includes/dynamic_css.php on line 6526 Warning: A non-numeric value encountered in /storage/content/01/2000401/glahi.se/public_html/wp-content/themes/Avada/includes/dynamic_css.php on line 6529

Extraction apparatus

///Extraction apparatus
­
    Warning: sizeof(): Parameter must be an array or an object that implements Countable in /storage/content/01/2000401/glahi.se/public_html/wp-content/plugins/woocommerce/includes/wc-conditional-functions.php on line 239
  • Extractor designed for EPA priority pollutant samples where the extracting solvent is heavier than water. Taller overall height allows longer solvent residence time, increasing efficiency. Measures: Flask cap. (ml), Approx. overall height x width (mm)


  • For use with solvents of greater specific gravity than the liquid being extracted. Unit is designed to provide one size extractor/condenser combination that will accomodate any flask size up to 2000 ml. Measures: Condenser length (mm), Extractor length (mm), Hose conn. (mm), Approx. overall height x width (mm)


  • Extractor designed for EPA priority pollutant samples where the extracting solvent is lighter than water. Taller overall height allows longer solvent residence time, increasing efficiency. Measures: Flask cap. (ml), Approx. overall height x width (mm)


  • Extractor designed for EPA priority pollutant samples where the extracting solvent is heavier than water. Both extraction and concentration are performed with the same apparatus. Complete with clamps. Measures: Approx. overall height x width (mm)


  • Extractor/Percolator

    3,053.00 kr

    Designed for routine extractions of plant and marine samples. Unit may be used with aqueous or organic solvents. Measures: Cap. (ml), Approx. overall height x width (mm)


  • Designed for use with Bevel-seal continuous liquid/liquid extractors with built-in concentrator. The adapter is inserted between the concentrator flask and the Snyder sidearm to provide an inline drying step in accordance with the EPA Contract Lab Program (CLP), where drying is required after extracting and before concentrating. Measures: NS Joint, Approx. height (mm), Bulb O.D. (mm)


  • Soxhlet

    1,951.00 kr

    Soxhlet-type extraction apparatus with a Friedrich condenser, used for the continuous extraction of solids with a suitable solvent. Improved design with a protected siphon tube, an enlarged vapor tube and sloping seals to prevent the trapping of liquid. Measures: Body I.D. x length (mm), Flask cap. (ml), Flask NS Joint, Condenser NS Joint, Approx. height (mm), Hose conn. (mm)


  • Soxhlet with stopcock

    1,355.00 kr

    Extractor with stopcock outlet for periodic solvent removal. Stopcock with 2 mm size bore. Measures: Body I.D. x length (mm), NS Joint Top, NS Joint Bottom, Approx. overall height (mm)


  • Soxhlet, body

    696.00 kr

    Extractor body only. Measures: Body I.D. x length (mm), Top NS Joint, Bottom NS Joint, Approx. overall height (mm)


  • The soxhlet body has a 28-415 GL thread sidearm and a 15-415 GL thread exit point from the siphon tube. Measures: Body I.D. x length (mm), Approx. overall height x width (mm)


  • Soxhlet/Dean Stark

    3,524.00 kr

    This apparatus combines two analytical techniques. Soxhlet extraction and Dean Stark azeotropic distillation into a single process for the removal of both water and CDDs/CDFs from wet particulate samples. Determination of both water and CDDs/CDFs on the same sample aliquot is achieved without the need for desiccation prior to Soxhlet extraction. Loss of analytes and sample contamination are avoided. Complete. Measures: Flask cap. (ml), Stopcock bore size (mm)